Company Culture  ꄲ  Analytical Inst.  ꄲ  Magnet-Schultz AWAX004D03 Inductive Position Transducer (±4 mm / 2-10 V / 4-20 mA)
ꁆ ꁇ

Magnet-Schultz AWAX004D03 Inductive Position Transducer (±4 mm / 2-10 V / 4-20 mA)

This model is an AWAX 004 series inductive position transducer with built-in electronics, ±4 mm measuring travel and 24 V DC ±10% supply with dual voltage and current output (2–10 V / 4–20 mA); cylindrical metal housing of Ø36 mm, centre-thread mounting, pressure-tight tube rated for 350 bar static pressure, M12×1 four-pole plug, IP65 protection and ±1% linearity, for travel measurement and travel control with proportional solenoids and valves.
online consultation

Product Details

I. Product Overview

This product is an AWAX 004 series inductive position transducer, a linear travel measuring element that can be flanged to a solenoid or to any other object to be measured, with the core moving inside the coils connected to the measured object through a threaded pin. It works on the differential transformer principle: the built-in electronics supply the primary coil, evaluate the voltage induced in the secondary coils and provide a defined output signal. Together with control electronics and a proportional solenoid it forms a complete travel control system.

In construction the sensor has a cylindrical metal housing of Ø36 mm outer diameter and about 67.75 mm body length with centre-thread mounting; it has a pressure-tight tube designed for 350 bar static pressure, and for applications under pressure an O-ring (9 × 15) seals between the pressure-tight tube and the solenoid or valve. Electrical connection is a M12×1, 4-pole round plug and the degree of protection is IP65 when properly mounted (DIN VDE 0470 / EN 60529); electronic zero-point adjustment and gain adjustment (sealed with securing varnish) are provided on the outside.

In performance terms the measuring path is ±4 mm, the supply is 24 V DC (±10%) with current consumption below 60 mA; the voltage port outputs 2–10 V and the current port 4–20 mA, with sensitivity of 1 V/mm (voltage) and 2 mA/mm (current); linearity tolerance is ±1%, the upper limiting frequency (3 dB) is typically 500 Hz, the reference temperature range is -20 to +75 °C and temperature drift is typically 0.05%/K; load resistance is above 5 kΩ with short-circuit-proof output, and the load on the current output is below 500 Ω. The device has been EMC tested to guideline 89/336/EWG and high-voltage tested to DIN VDE 0580 (short-circuited connector pins against housing).

II. Specifications

表格

Parameter Value
Model AWAX004D03
Product Type Inductive position transducer (differential transformer principle, built-in electronics)
Measuring Path ±4 mm
Supply Voltage 24 V DC ±10%
Current Consumption <60 mA
Output (dual voltage/current port) 2–10 V / 4–20 mA
Sensitivity 1 V/mm (voltage); 2 mA/mm (current)
Linearity Tolerance ±1%
Upper Limiting Frequency (3 dB) Typically 500 Hz
Reference Temperature Range -20 to +75 °C
Temperature Drift Typically 0.05%/K
Load Resistance >5 kΩ (short-circuit proof output)
Load on Current Output <500 Ω
Housing Cylindrical metal housing, Ø36 mm, body length approx. 67.75 mm
Mounting Centre thread mounting
Electrical Connection Round plug M12×1, 4-pole
Degree of Protection IP65 when properly mounted (EN 60529)
Static Pressure 350 bar (pressure-tight tube design)
Sealing O-ring 9 × 15
Core Connection Threaded pin M10×1
EMC 89/336/EWG
High-Voltage Test DIN VDE 0580

V. Model Description

Per the official type code, AWAX 004 means: A (equipment group) — W (travel type) — A (voltage and current port, U for voltage port only) — X (centre mounting, F for flange mounting) — 004 (measuring range ±4 mm), followed by the design number. The design number of this model is D03 and the official pamphlet does not state its differences, so the electrical and mechanical data follow the AWAX 004 series general data. In Rexroth spare part channels this model is also listed as material number R902471376 (AWAX004D03 A4 40/125/180); that is a spare part channel listing, so the nameplate should be checked when ordering.

VI. Why Choose Us

  • Professional channel supply covering Magnet-Schultz position transducers and proportional solenoid accessories
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What is the measuring travel?

A: ±4 mm.

Q2: What output signals are provided?

A: Dual voltage and current ports, 2–10 V and 4–20 mA.

Q3: Can it be used under pressure?

A: Yes, the pressure-tight tube design withstands 350 bar static pressure with O-ring sealing.

Q4: What are the electrical connection and degree of protection?

A: M12×1 four-pole round plug, IP65 when properly mounted.